The Ultimate Power Protection Solution: UPS Designs for Bruker AXS Systems by NXT Power

KS Analytical Systems is proud to present a new, total UPS solution for clinical and diagnostic laboratory systems, specifically designed for Bruker AXS, by NXT Power. The Integrity Max & Pro UPS is a complete power protection solution providing isolation, power conditioning, and backup protection for Bruker AXS systems. Regardless of input fluctuations, the Integrity series ensures that the output remains continuous and regulated. The industry-leading UPS line is built to power sophisticated computer loads–systems with high inrush

Mystery crystals

Curiosity may have killed the cat, but it’s the lifeblood of a well-functioning analytical lab. A few days ago, Todd was preparing a water chiller for shipping and washed out some corrosion products with acetic acid. The resulting solution was left in a beaker over the weekend and when we returned, he noticed that it had formed rather large crystals. So he did what any curious person with a lab full of XRD instrumentation would do. He ground it up

What’s really coming out of my XRD tube?

We’ve been experimenting with better ways to quantify the quality of XRD tubes in the shop. We use these tests on new and used tubes to monitor performance in two key areas. 1) Intensity 2) Spectral purity. What we’ve settled on is a test that involves a wavelength-dispersive approach which gives us a lot of intensity to work with while eliminating background scatter and fluorescence effects. Basically, we’re able to extract more information from the data because the “noise” is almost

Bruker D2 Phaser Sample Holders

KS Analytical Systems now offers custom sample holders for the Bruker D2 Phaser 6-position autosampler. These can be finished to order with any depth and diameter of well or a zero-background plate (ZBH) with or without a well ground in the surface.

Fully digital autosampler install

Another fully-rebuilt, digital autosampler out in the wild. This one is on a system that already has one of our Si-Drift Detectors and an awesome ICDD Jade Pro/PDF-4+ software package. We’ve got all the fancy new hardware at our in-house lab, but when we need the absolute best data, this is our goto configuration.

Sample holders for Rigaku Miniflex systems

KS Analytical Systems now offers custom sample holders for Rigaku Miniflex systems. The 6-position autosamplers and rotation stages (and even some fixed stages) make use of the magnetic disk design for holding powder without taking up much extra room in the diminutive benchtop. Top-loadingRear-loadingZero-background

KS Analytical Systems now offers new Bruker XRD and XRF hardware


Deprecated: preg_match_all(): Passing null to parameter #2 ($subject) of type string is deprecated in /media/websites/ksawp2/wp-includes/media.php on line 1868

Deprecated: preg_split(): Passing null to parameter #2 ($subject) of type string is deprecated in /media/websites/ksawp2/wp-includes/formatting.php on line 3479

Energy-dispersive detector systems for XRD applications

Energy resolution 140eV under ideal conditions. All KB peaks eliminated electronically. W LA1 (8.40 KeV) lines eliminated from Cu KA1,2 (8.04 KeV) scans even with thoroughly contaminated tubes. Common fluorescence energies (i.e. Fe when Cu tube anodes are used) are greatly reduced. (Brehmstralung effects are impossible to remove completely) Most PSD detectors offer no better than 650eV. This allows for a great deal of fluorescence energy to pass as well as W LA1 from older Cu tubes. Low angle scatter The detector mounts in place of the